Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Am J Vet Res ; : 1-8, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38663446

RESUMEN

OBJECTIVE: To evaluate the diagnostic value of pulmonary-vein-to-pulmonary-artery ratio (PV:PA) in dogs with myxomatous mitral valve degeneration (MMVD), classified according to the American College of Veterinary Internal Medicine (ACVIM) consensus guidelines. ANIMALS: 80 client-owned dogs with either MMVD (n = 65) or no cardiovascular disease (control group; n = 15) between August 5, 2020, and July 19, 2023. METHODS: This is a retrospective study. Dogs with MMVD were classified according to ACVIM consensus guidelines. Echocardiograms, thoracic radiographs, and other measurements needed in this study were reviewed in all dogs. Spearman correlation was used to determine the correlation between the PV:PA and the following variables: vertebral heart size, vertebral left atrial size, left-atrium-to-aorta ratio, normalized left ventricular internal diameter, and peak transmitral early diastolic velocity. Receiver operating characteristic (ROC) curve analysis was used to evaluate the value of PV:PA in distinguishing between stages B1 and B2 and stages B2 and C. RESULTS: All conventional indices showed correlations with PV:PA. The area under the ROC curve (AUC) for stages B1 and B2 was 0.83, and the cutoff value for differentiating stage B2 was 1.52. The AUC for stages B2 and C was 0.81, and the cutoff value for differentiating stage C was 2.09. CLINICAL RELEVANCE: PV:PA was significantly different between control and the stage B1 group, stage B1 and B2 group, and stage B2 and C group. PV:PA can be an index that can be used in evaluating MMVD dogs.

2.
Sensors (Basel) ; 19(13)2019 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-31262081

RESUMEN

In this paper, a wide dynamic range (WDR) CMOS image sensor (CIS) with a charge splitting gate (SG) and two storage diodes (SDs) is presented. By using single-gate on/off control with the SG, photocurrent path to the first (SD1) or second storage diodes (SD2) is switched alternatively and periodically during exposure and signal electrons generated in a photodiode (PD) are transferred to and accumulated in the SD1 or SD2. By setting a large ratio of the off-time to on-time of the SG, two different sensitivity signals, which are originated by the same photodiode, are generated and a WDR image signal is obtained. This technique has a distinct advantage on mitigating the problem of motion artifact in WDR imaging with high and low sensitivity signals and flexible dynamic control of the dynamic range. An experimental WDR CMOS image sensor with 280 (H) × 406 (V)-pixel array consisting of 14 sub-arrays, each of which have 20 (H) × 406 (V) pixels, was implemented and tested. For the SG on/off-time ratio of 30 and 279, the DR of 93 dB and 104 dB, respectively, was demonstrated. The effect of the proposed WDR imaging operation on the reduced motion artifact was experimentally confirmed.

3.
Sensors (Basel) ; 18(4)2018 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-29587424

RESUMEN

A probabilistic method to remove the random telegraph signal (RTS) noise and to increase the signal level is proposed, and was verified by simulation based on measured real sensor noise. Although semi-photon-counting-level (SPCL) ultra-low noise complementary-metal-oxide-semiconductor (CMOS) image sensors (CISs) with high conversion gain pixels have emerged, they still suffer from huge RTS noise, which is inherent to the CISs. The proposed method utilizes a multi-aperture (MA) camera that is composed of multiple sets of an SPCL CIS and a moderately fast and compact imaging lens to emulate a very fast single lens. Due to the redundancy of the MA camera, the RTS noise is removed by the maximum likelihood estimation where noise characteristics are modeled by the probability density distribution. In the proposed method, the photon shot noise is also relatively reduced because of the averaging effect, where the pixel values of all the multiple apertures are considered. An extremely low-light condition that the maximum number of electrons per aperture was the only 2 e - was simulated. PSNRs of a test image for simple averaging, selective averaging (our previous method), and the proposed method were 11.92 dB, 11.61 dB, and 13.14 dB, respectively. The selective averaging, which can remove RTS noise, was worse than the simple averaging because it ignores the pixels with RTS noise and photon shot noise was less improved. The simulation results showed that the proposed method provided the best noise reduction performance.

4.
IEEE Trans Biomed Circuits Syst ; 11(6): 1335-1343, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28945601

RESUMEN

A large full well capacity (FWC) for wide signal detection range and low temporal random noise for high sensitivity lock-in pixel CMOS image sensor (CIS) embedded with two in-pixel storage diodes (SDs) has been developed and presented in this paper. For fast charge transfer from photodiode to SDs, a lateral electric field charge modulator (LEFM) is used for the developed lock-in pixel. As a result, the time-resolved CIS achieves a very large SD-FWC of approximately 7ke-, low temporal random noise of 1.2e-rms at 20 fps with true correlated double sampling operation and fast intrinsic response less than 500 ps at 635 nm. The proposed imager has an effective pixel array of and a pixel size of . The sensor chip is fabricated by Dongbu HiTek 1P4M 0.11 CIS process.


Asunto(s)
Técnicas Biosensibles/métodos , Semiconductores , Diseño de Equipo
5.
Sensors (Basel) ; 16(11)2016 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-27827972

RESUMEN

This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS) technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs). This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC). The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median): 0.29 e-rms) when compared with the CMS gain of two (2.4 e-rms), or 16 (1.1 e-rms).

6.
Biosens Bioelectron ; 86: 135-142, 2016 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-27348778

RESUMEN

Ultrasensitive, rapid and selective diagnostic probes are urgently needed to overcome the limitations of traditional probes for norovirus (NV). Here, we report the detection of NV genogroup II via nucleic acid hybridization technology using a quantum dot (QD)-conjugated molecular beacon (MB) probe. To boost the sensitivity of the MB assay system, an ultrasensitive QD fluorophore with unique optical properties was synthesized, characterized and exploited as a fluorescence signal generator. Alloyed thioglycolic (TGA)-capped CdZnSeS QDs with a high photoluminescence (PL) quantum yield (QY) value of 92% were synthesized, and a modified silanization method was employed to encapsulate the thiol-capped QDs in a silica layer. The resulting highly luminescent alloyed SiO2-coated CdZnSeS QDs had a remarkable PL QY value of 98%. Transmission electron microscopy and dynamic light scattering confirmed the monodispersity of the alloyed nanocrystals, and zeta potential analysis confirmed their colloidal stability. Powder X-ray diffraction and PL lifetime measurements confirmed the surface modification of the QDs. The alloyed TGA-capped and SiO2-coated CdZnSeS QD-conjugated MB bioprobes detected extremely low concentrations of NV RNA. Ultrasensitive detection of low concentrations of NV RNA with a limit of detection (LOD) of 8.2copies/mL in human serum and a LOD of 9.3 copies/mL in buffer was achieved using the SiO2-coated CdZnSeS QD-MB probes, an increase in sensitivity of 3-fold compared with the detection limit for NV RNA using TGA-capped CdZnSeS QD-MBs. The additional merits of our detection system are rapidity, specificity and improved sensitivity over conventional molecular test probes.


Asunto(s)
Técnicas Biosensibles/instrumentación , Compuestos de Cadmio/química , Nanotecnología/instrumentación , Norovirus/aislamiento & purificación , Puntos Cuánticos , ARN Viral/sangre , Compuestos de Selenio/química , Materiales Biocompatibles Revestidos/síntesis química , Diseño de Equipo , Análisis de Falla de Equipo , Técnicas de Sonda Molecular/instrumentación , Sondas Moleculares/síntesis química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Silicio/química , Dióxido de Silicio/química , Compuestos de Zinc/química
7.
Opt Express ; 24(4): 4155-76, 2016 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-26907065

RESUMEN

In the work described in this paper, an image reproduction scheme with an ultra-high-speed temporally compressive multi-aperture CMOS image sensor was demonstrated. The sensor captures an object by compressing a sequence of images with focal-plane temporally random-coded shutters, followed by reconstruction of time-resolved images. Because signals are modulated pixel-by-pixel during capturing, the maximum frame rate is defined only by the charge transfer speed and can thus be higher than those of conventional ultra-high-speed cameras. The frame rate and optical efficiency of the multi-aperture scheme are discussed. To demonstrate the proposed imaging method, a 5×3 multi-aperture image sensor was fabricated. The average rising and falling times of the shutters were 1.53 ns and 1.69 ns, respectively. The maximum skew among the shutters was 3 ns. The sensor observed plasma emission by compressing it to 15 frames, and a series of 32 images at 200 Mfps was reconstructed. In the experiment, by correcting disparities and considering temporal pixel responses, artifacts in the reconstructed images were reduced. An improvement in PSNR from 25.8 dB to 30.8 dB was confirmed in simulations.

8.
J Mater Chem B ; 4(8): 1489-1498, 2016 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-32263115

RESUMEN

Controlling and engineering the particle composition of semiconductor alloys is one of the topmost targets in the field of semiconductor materials science and technology. Quantum dot (QD) nanocrystals offer an unmatched opportunity to obtain a wide range of composition-controlled alloys and have captivated a great deal of interest recently. Herein, we report on band gap engineering via tuning and controlling the sulphur molar fraction (ternary shell layer) of quaternary/ternary core/shell alloyed CdZnSeS/ZnSeS QDs. Varying optical properties were exhibited by the alloyed QDs but a uniform particle size distribution was maintained across all the compositions. The alloyed QDs displayed bright emission colours under UV irradiation, whereas the photoluminescence quantum yields (PL QY) were in a remarkable range of 36-98%. Non-linearity of the lattice parameter was an indication of gradient alloying of the nanocrystals, whereas the kinetics of the optical properties unravelled the effect of intrinsic optical bowing. Displacement of bond length and anion mismatch influenced the optical properties of the QDs with respect to the variation in the PL QY. Alloyed CdZnSeS/ZnSe1.0S1.3 QDs with a spectacular PL QY were exploited as an ultrasensitive fluorescence reporter in a conjugated molecular beacon (MB) assay to detect influenza virus H1N1 RNA. Our detection system was rapid and highly sensitive for detecting extremely low concentrations of H1N1 RNA (down to 2 copies per mL), specific and versatile (detects H1N1 RNA in human serum). For proof of concept, the alloyed CdZnSeS/ZnSe1.0S1.3 QD-MB bioprobe exhibited a superior 12-fold sensitivity over an alloyed CdZnSeS-MB probe, while a conventional CdSe/ZnS-MB probe could not detect extremely low concentrations of influenza virus H1N1 RNA.

9.
BMC Gastroenterol ; 15: 110, 2015 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-26330262

RESUMEN

BACKGROUND: It is important to devise efficient and easy methods of detecting colorectal tumours to reduce mortality from colorectal cancer. Dual-wavelength excitation autofluorescence intensity can be used to visualize colorectal tumours. Therefore, we evaluated dual-wavelength excitation autofluorescence images of colorectal tumours obtained with a newly developed, high-sensitivity complementary metal-oxide-semiconductor (CMOS) imager. METHODS: A total 107 colorectal tumours (44 adenomas, 43 adenocarcinomas with intramucosal invasion, and 20 sessile serrated adenoma/polyps [SSA/Ps]) in 98 patients who underwent endoscopic tumour resection were included. The specimens were irradiated with excitation light at 365 nm and 405 nm, and autofluorescence images measured with a 475 ± 25-nm band pass filter were obtained using a new, high-sensitivity CMOS imager. Ratio images (F365ex/F405ex) were created to evaluate the lesion brightness compared with that of normal mucosa, and specimens were categorized into a no signal or high signal group. RESULTS: Adenomas and adenocarcinomas were depicted in 87 ratio images, with 86.2% (n = 75) in the High signal group. SSA/P was depicted in 20 ratio images, with 70.0% (n = 14) in the High signal group. CONCLUSIONS: Dual-wavelength excitation autofluorescence images of colorectal tumours can be acquired using our high-sensitivity CMOS imager, and are useful in detecting colorectal tumours.


Asunto(s)
Adenocarcinoma/diagnóstico , Adenoma/diagnóstico , Pólipos del Colon/diagnóstico , Neoplasias Colorrectales/diagnóstico , Imagen Óptica/métodos , Anciano , Estudios Transversales , Femenino , Fluorescencia , Humanos , Masculino , Persona de Mediana Edad , Imagen Óptica/instrumentación , Semiconductores
10.
Sensors (Basel) ; 14(1): 1528-43, 2014 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-24441768

RESUMEN

In extremely low-light conditions, random telegraph signal (RTS) noise and dark current white defects become visible. In this paper, a multi-aperture imaging system and selective averaging method which removes the RTS noise and the dark current white defects by minimizing the synthetic sensor noise at every pixel is proposed. In the multi-aperture imaging system, a very small synthetic F-number which is much smaller than 1.0 is achieved by increasing optical gain with multiple lenses. It is verified by simulation that the effective noise normalized by optical gain in the peak of noise histogram is reduced from 1.38e⁻ to 0.48 e⁻ in a 3 × 3-aperture system using low-noise CMOS image sensors based on folding-integration and cyclic column ADCs. In the experiment, a prototype 3 × 3-aperture camera, where each aperture has 200 × 200 pixels and an imaging lens with a focal length of 3.0 mm and F-number of 3.0, is developed. Under a low-light condition, in which the maximum average signal is 11e⁻ per aperture, the RTS and dark current white defects are removed and the peak signal-to-noise ratio (PSNR) of the image is increased by 6.3 dB.

11.
Opt Express ; 21(2): 1417-29, 2013 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-23389123

RESUMEN

Multi-beam confocal microscopy without any physical pinhole was demonstrated. As a key device, a custom CMOS image sensor realizing a focal-plane pinhole array effect by special pixel addressing and discarding of the unwanted photocarriers was developed. The axial resolution in the confocal mode measured by FWHM for a planar mirror was 8.9 µm, which showed that the confocality has been achieved with the proposed CMOS image sensor.


Asunto(s)
Aumento de la Imagen/instrumentación , Iluminación/instrumentación , Microscopía Confocal/instrumentación , Semiconductores , Procesamiento de Señales Asistido por Computador/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...